Location: Akron Lumber, Akron
0 $0.00
items in your cartto quote To cart
Ooops no items were found.
Try something else.
Ok
Loading…

GFCI Duplex Receptacle, 2 -Pole, 15 A, 125 V, Back, Side Wiring, NEMA: 5-15R, Ivory

Category Outlets
7335698

GFCI Duplex Receptacle, 2 -Pole, 15 A, 125 V, Back, Side Wiring, NEMA: 5-15R, Ivory

Item Code: 7335698
Category Outlets

Description

Eaton's Arrow Hart line of GFCI receptacles ensure electrical shock protection with periodical automatic testing. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. GFCIs provide state-of-the-art, dependable electrical shock protection. In addition to being tested to the highest standards to help ensure safety, Arrow Hart GFCIs will deny power and prevent re-setting if the device is no longer able to provide safe, protected power.


Product Details

  • Color: Ivory
  • Current Rating: 15 A
  • Dimensions: 4.2 in L x 1.68 in W x 1.27 in D
  • Frequency Rating: 60 Hz
  • Includes: Wallplate
  • Material: Polypropylene
  • Mounting Type: Wall
  • N E M A Configuration: 5-15R
  • Number of Poles: 2
  • Number Of Wires: 3
  • Operating Temperature: -35 to 66 deg C
  • Voltage Rating: 125 V
  • Wire Size: 14 to 10 AWG
  • Wiring Type: Back Side


Features

  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or "end of life" condition
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
  • Ground termination with back wire clamp provides secure wiring and reduces installation time
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide great aesthetics
  • Tapered back wire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire
  • When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
  • Line-load miswiring protection


Specifications

Weight

0.37lb

Brand

Eaton

Category

Outlets

UPC Code

032664742378

Shipping and Pickup Options
Multiple Shipping options available:

UPS/USPS Shipping: 3-5 day delivery.

Store to Door Delivery: Within 30 miles.

Swift In-Store Pickup: Ready in 1 hour!

Starting from
$0.00 / EA
/
- +
Your Pick-Up location is Akron Lumber, Akron
Compare

GFCI Duplex Receptacle, 2 -Pole, 15 A, 125 V, Back, Side Wiring, NEMA: 5-15R, Ivory

Category Outlets
7335698

GFCI Duplex Receptacle, 2 -Pole, 15 A, 125 V, Back, Side Wiring, NEMA: 5-15R, Ivory

Item Code: 7335698
Category Outlets

Description

Eaton's Arrow Hart line of GFCI receptacles ensure electrical shock protection with periodical automatic testing. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. GFCIs provide state-of-the-art, dependable electrical shock protection. In addition to being tested to the highest standards to help ensure safety, Arrow Hart GFCIs will deny power and prevent re-setting if the device is no longer able to provide safe, protected power.


Product Details

  • Color: Ivory
  • Current Rating: 15 A
  • Dimensions: 4.2 in L x 1.68 in W x 1.27 in D
  • Frequency Rating: 60 Hz
  • Includes: Wallplate
  • Material: Polypropylene
  • Mounting Type: Wall
  • N E M A Configuration: 5-15R
  • Number of Poles: 2
  • Number Of Wires: 3
  • Operating Temperature: -35 to 66 deg C
  • Voltage Rating: 125 V
  • Wire Size: 14 to 10 AWG
  • Wiring Type: Back Side


Features

  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or "end of life" condition
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
  • Ground termination with back wire clamp provides secure wiring and reduces installation time
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide great aesthetics
  • Tapered back wire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire
  • When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
  • Line-load miswiring protection


Specifications

Weight

0.37lb

Brand

Eaton

Category

Outlets

UPC Code

032664742378

Shipping and Pickup Options
Multiple Shipping options available:

UPS/USPS Shipping: 3-5 day delivery.

Store to Door Delivery: Within 30 miles.

Swift In-Store Pickup: Ready in 1 hour!

Starting from
$0.00 / EA
/
- +
Your Pick-Up location is Akron Lumber, Akron
Compare
SEARCH ×